Adjusting the Printhead
7. Align the Angle Adjustment Lever with the red square and close the T op Cover .
A test pattern is printed for adjustment.
Important
Do not touch the Linear Scale (a) or Carriage Shaft (b). T ouching these parts may damage them.
If you accidentally move the Carriage , you will hear a warning tone. In this case, close the T op Cover .
8. Examine the test pattern for adjustment. Determine the straightest set of lines.
9. Open the T op Cover and move the Angle Adjustment Lever to match the number (or the square)
of the straightest set of lines.
If no single set of lines is perfectly straight, move the Angle Adjustment Lever to a position
between the numbers (or between the number and the square) of the two sets of lines that
are least misaligned.