Chapter 5
5-5
F-5-7
5.4 Error Code
5.4.1 Outline
5.4.1.1 Error Code Outline
0008-3126
An error code is used to indicate a fault in a machine, and is indicated in the machine's LCD or reports, showing the nature (symptoms) of the fault. Using the error
code, the user or the service man can readily find out how to correct the fault by simply referring to the User's Manual or service manual.
An error code may be either of the following two types:
User Error Codes
A fault indicated as a user error code is one that can easily be corrected by the user, as by operating the machine. It takes the form of "#+number."
Service Error Codes
If a fault calls for a service man for correction, it is indicated as a service man error code in the form of "##+number" or "SYSTEM ERROR E+number."
Memo
A service error code expressed in the form of "##+number" will not appear on the LCD, Error Tx Report, or Activity Report while the machine remains
in factory default state. To check a service error code, shift bit 0 of service soft switch #1 SSSW SW01 to '1'.
5.4.1.2 Service Error Code
0008-3131
The descriptions on service error codes in this Manual are limited to “SYSTEM ERROR E + numeral.”
For descriptions on “## + numeral,” see the separately available G3/G4 Facsimile Error Code Service Handbook.
The following is a list of service error codes (SYSTEM ERROR E + numeral):
T-5-3
Code Main cause/description Remedial action
E000 fixing assembly faulty start-up (open circuit
in the main thermistor)
Check the connector of the fixing film unit.
Replace the fixing film unit.
Replace the DCNT Borad PCB.
fixing assembly faulty start-up (open circuit
in the sub thermistor)
fixing assembly faulty start-up (open circuit
in the fixing heater)
E001 fixing heater overheating (short-circuit in
the main thermistor)
Check the connector of the fixing film unit.
Replace the fixing film unit.
Replace the DCNT Borad.
fixing heater overheating (short-circuit in
the sub thermistor)
E002 fixing assembly low temperature (open
circuit in the main thermistor)
Check the connector of the fixing film unit.
Replace the fixing film unit.
eplace the DCNT Borad.
fixing assembly low temperature (open
circuit in the sub thermistor)
fixing assembly low temperature (open
circuit in the fixing heater)
J301
J204
J203
J201
J202
CN2
CN1
CN105
J1
J3
J3
J13
J4
J1
JBAT2
JBAT1
JPSU1
JNCU1
JNCU2
CCD
JLBP1
J8
J3
J10
J712
J125
J127
J21
J1
J205
J401
J101
J1
J5
J6
J4
J2
J23
Vue de la page 276