System
Quadruple mass spectrometer that can be used for various types
of analysis through retrotting it with other equipment:
Ordering information
Product
code
Trade name
Remarks
Model name Product name
20110 M-401QA-MGSY Quadruple mass spectrometer (gas introduction type ion source) Gas introduction type (box type), high-speed sweep, Y203-FIL
20111 M-401QA-MUSY Quadruple mass spectrometer (UHV type ion source) UHV type (cage type), high-speed sweep, Y203-FIL
20012 M-401QA-MGHY Quadruple mass spectrometer (gas introduction type ion source) Gas introduction
type (box type), high sensitivity, Y203-FIL
20013 M-401QA-MUHY Quadruple mass spectrometer (UHV type ion source/Y203) UHV type (cage type), high sensitivity, Y203-FIL
20090 M-201QA-TDM (W) Quadruple mass spectrometer 200 amu, M type, W-FIL, an AC adapter included, no communication cable *
20091 M-201QA-TDM (Y) Quadruple mass spectrometer 200 amu, M type, Y-FIL, an AC adapter included, no communication cable *
20092 M-101QA-TDM (W) Quadruple mass spectrometer 100 amu, M type, W-FIL, an AC adapter included, no communication cable *
20093 M-101QA-TDM (Y) Quadruple mass spectrometer 100 amu, M type, Y-FIL, an AC adapter included, no communication cable *
20094 M-101QA-TDF (W) Quadruple mass spectrometer 100 amu, F type, W-FIL, an AC adapter included, no communication cable *
20095 M-101QA-TDF (Y) Quadruple mass spectrom
eter 100 amu, F type, Y-FIL, an AC adapter included, no communication cable *
20190 M-201QA-TDM (Re) Quadruple mass spectrometer (box type ion source) 200 amu, M type, Re-FIL, a box type ion source, an AC adapter included, no
communication cable *
20191 M-101QA-TDM (Re) Quadruple mass spectrometer (box type ion source) 100 amu, M type, Re-FIL, a box type ion source, an AC adapter included, no
communication
cable *
20096 M-070QA-TDF Quadruple mass spectrometer Configuration: An analyzer tube, a controller, an AC adapter, and software
(QUADVISION)
20493 Ion source for M-070 For maintenance
20290 RS-232C cable for quadruple mass spectrometer (1.5 m)
20291 RS-232C cable for quadruple mass spectrometer (3 m)
20292 RS-232C cable for quadruple mass spectrometer (5 m)
20293 RS-232C cable for quadruple mass spectrometer (
10 m)
20296 RS-485 cable for quadruple mass spectrometer (5 m) RS-485 cable (5 m) + Y cable
20297 RS-485 cable for quadruple mass spectrometer (10 m) RS-485 cable (10 m) + Y cable
20298 RS-485 cable for quadruple mass spectrometer (15 m) RS-485 cable (15 m) + Y cable
RS-232C conversion
PARANI-SD1000 Serial number BLUETOOTH conversion adapter BLUETOOTH specifications of QUADVISION3 MOBILE
20299 RS-485 cable for q
uadruple mass spectrometer (20 m) RS-485 cable (20 m) + Y cable
20390 RS-485 card
20391 RS-485 board
20392 COM-1PD (USB) H COM-1PD (USB) H USB-RS485 converter
20395 AC adapter extension cable (5 m) For M-101/201QA: The AC adaptor cable extension can also be used with the 070.
20396 AC adapter extension cable (10 m) For M-101/201QA: The AC adaptor cable extension can also be used with the 070.
20397 AC adapter ext
ension cable (15 m) For M-101/201QA: The AC adaptor cable extension can also be used with the 070.
20398 AC adapter extension cable (20 m) For M-101/201QA: The AC adaptor cable extension can also be used with the 070.
20418 NIST library data conversion software for M-QA For M-100/200/400QA
20490 TD-W-FIL Wlament for quadruple mass spectrometer For M-101/201
20491 TD-Y-FIL Ylament for quadruple mass spectrom
eter For M-101/201
20492 TD-Re-FIL Re filament for quadruple mass spectrometer (for box type ion
source)
For M-101/201
20130 401G-Y203-FIL QMS401-FILAMENT-Y203 GAS INTRODUCTION TYPE
20131 401U-Y203-FIL QMS401-FILAMENT-Y203 UHV TYPE
30111 V-040LV-MMI DN40 manual L-shape valve MSB Protective valve for M-101/201
Simplified gas analysis system that utilizes a differential pump
- Incorporation of a pump system (TMP + MP) enables the analysis of
gasses at pressures not within the normal operating range of a quadruple
mass spectrometer, such as processing pressure or atmospheric pressure.
- Depending on the application a quadruple mass spectrometer or gas
introduction system, etc. can be retrofitted.
Compact gas analysis system M-070/101/201/401GA-D series
Residue analysis in various
types of vacuum equipment
Process gas analysis
Inorganic gas analysis
Thermal desorption spectrometry
Gas analysis for research and
development
Applications
February 2011
Vue de la page 0
1 2 3 4 5 6 7 8

Résumé du contenu

Page 1 - ●M-401QA-MU/G

●M-070QA-TDF●M-101QA-TDF●M-101/201QA-TDM●M-401QA-MU/G SystemQuadruple mass spectrometer that can be used for various types of analysis through retro

Page 2 - Quadruple mass spectrometers

Application field M-070QA-TDF M-101QA-TDF M-101QA-TDM M-201QA-TDM Residual gas monitoring in PVD process equipment ◎ ◎ ◎ ○Residual gas monitoring i

Page 3 - ■ Specifications

Dimensional outline drawing SpecificationsModel nameStandard model High-sensitivity modelM-070QA-TDF M-101QA-TDF M-101QA-TDM M-201QA-TDMBasic perfo

Page 4

Features1. High-speed measurements. (M- 401QA-MGSY/MUSY) Data of M/e = 1 to 400 obtained in just one second.2. Two types of ion sources Supports bo

Page 5 - Analyzer tube

Dimensional outline drawingModel nameHigh-sensitivity measurement High-speed measurementM-401QA-MGHY M-401QA-MUHY M-401QA-MGSY M-401QA-MUSYBasic per

Page 6 - QUADVISION 3

Details of QUADVISION 3Software designed for quadruple mass spectrometersQUADVISION 3Easy measurements via simple operationApplicable quadruple mass

Page 7 - QUADVISION 3 Mobile

Details of QUADVISION 3 MobileMobile software designed for quadruple mass spectrometersQUADVISION 3 MobileSimplied mobile software of QUADVISION 3E

Page 8

●M-070QA-TDF●M-101QA-TDF●M-101/201QA-TDM●M-401QA-MU/G SystemQuadruple mass spectrometer that can be used for various types of analysis through retro

Commentaires sur ces manuels

Pas de commentaire