Resetting the Counters
Make sure to reset the scanner’s internal counters using the following
procedure whenever you replace the feed roller or separation pad.
IMPORTANT
This section describes the procedure to use when the Auto Start
switch on the rear panel of the scanner is set to the “OFF” position.
If the Auto Start switch is set to the “ON” position (when you only use
CaptureOnTouch Lite and have not installed CaptureOnTouch and
the scanner driver on your computer), you cannot reset the counter
using this procedure. In this case, you can reset the counter from
CaptureOnTouch Lite. For details, see p. 41 (Windows) or see p. 72
(Mac OS X).
Under Windows
1
Start Windows and log in as a user with administrator
privileges.
2
Click the Start button, and then click [All Programs],
[Canon P-215], and [Canon imageFORMULA Utility].
imageFORMULA Utility starts.
3
Click [CANON P-215 USB] and click [Properties].
The scanner’s properties appear.
4
Click the [Maintenance] tab, and reset the counters.
If you replaced the feed rollers, click [Reset] for [Current Rollers].
If you replaced the separation pad, click [Reset] for [Current Pad].